Know Your Environment. Protect Your Health.

UTILITY

Emil-mar Subdivision

location

Ocala, Florida

serves

255

source

Groundwater

data through

2025

EWG 2026 Data Set

Overview

EWG's drinking water quality report shows results of tests conducted by the water utility and provided to the Environmental Working Group by the Florida Department of Environmental Protection, as well as information from the U.S. EPA Enforcement and Compliance History database (ECHO). For the latest quarter assessed by the U.S. EPA (January 2026- March 2026), tap water provided by this water utility was in compliance with federal health-based drinking water standards.

Contaminants Detected

Haloacetic acids (HAA5)

Potential Effect: cancer

This Utility: 10.3 ppb

103x

EWG's Health Guideline: 0.1 ppb

Haloacetic acids (HAA5)

Haloacetic acids are formed when disinfectants such as chlorine are added to tap water. The group of five haloacetic acids regulated by federal standards includes monochloroacetic acid, dichloroacetic acid, trichloroacetic acid, monobromoacetic acid and dibromoacetic acid.

Haloacetic acids (HAA5) was found at 103 times above EWG's Health Guideline.

EWG Health Guideline

0.1 ppb or less

This Utility

10.3 ppb

Legal Limit

60 ppb

National Average

16.1 ppb

State Average

18.3 ppb

Health Risks

The EWG Health Guideline of 0.1 ppb for the group of five haloacetic acids, or HAA5, was defined in a peer-reviewed scientific study by EWG and represents a one-in-a-million lifetime cancer risk level. This health guideline protects against cancer.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2023-2025.

ppb = parts per billion

Pollution Sources

Treatment Byproducts

Filtering Options

Activated Carbon

Reverse Osmosis

Nitrate

Potential Effect: cancer

This Utility: 5.47 ppm

39x

EWG's Health Guideline: 0.14 ppm

Nitrate

Nitrate, a fertilizer chemical, frequently contaminates drinking water due to agricultural and urban runoff, and discharges from municipal wastewater treatment plants and septic tanks. Excessive nitrate in water can cause oxygen deprivation in infants and increase the risk of cancer. Click here to read more about nitrate.

Nitrate was found at 39 times above EWG's Health Guideline.

EWG Health Guideline

0.14 ppm or less

This Utility

5.47 ppm

Legal Limit

10 ppm

National Average

0.814 ppm

State Average

0.252 ppm

Health Risks

The EWG health guideline of 0.14 parts per million, or ppm, for nitrate and nitrite is based on the equivalent health guideline for nitrate, as defined in a peer-reviewed scientific study by EWG. This guideline represents a one-in-one-million annual cancer risk level.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2023-2025.

ppm = parts per million

Pollution Sources

Agriculture

Runoff & Sprawl

Naturally Occurring

Filtering Options

Reverse Osmosis

Ion Exchange

Total trihalomethanes (TTHMs)

Potential Effect: cancer

This Utility: 40.5 ppb

270x

EWG's Health Guideline: 0.15 ppb

Total trihalomethanes (TTHMs)

Trihalomethanes are cancer-causing contaminants that form during water treatment with chlorine and other disinfectants. The total trihalomethanes group includes four chemicals: chloroform, bromodichloromethane, dibromochloromethane and bromoform.

Total trihalomethanes (TTHMs) was found at 270 times above EWG's Health Guideline.

EWG Health Guideline

0.15 ppb or less

This Utility

40.5 ppb

Legal Limit

80 ppb

National Average

28.9 ppb

State Average

30 ppb

Health Risks

The health guideline of 0.15 parts per billion, or ppb, for the group of four trihalomethanes, or THM4/TTHM, was defined in a peer-reviewed scientific study by EWG and represents a one-in-one-million lifetime cancer risk level.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2023-2025.

ppb = parts per billion

Pollution Sources

Treatment Byproducts

Filtering Options

Activated Carbon

Reverse Osmosis

Includes chemicals detected in 2023-2025 for which annual utility averages exceeded an EWG-selected health guideline established by a federal or state public health authority.


† HAA5 is a contaminant group that includes monochloroacetic acid, dichloroacetic acid, trichloroacetic acid, monobromoacetic acid and dibromoacetic acid. HAA9 is a contaminant group that includes the chemicals in HAA5 and bromochloroacetic acid, bromodichloroacetic acid, chlorodibromoacetic acid and tribromoacetic acid. TTHM is a contaminant group that includes bromodichloromethane, bromoform, chloroform and dibromochloromethane.

Fluoride

This Utility: 0.0420 ppm

No EWG Health Guideline

Fluoride

Fluoride occurs naturally in surface and groundwater and is also added to drinking water by many water systems to prevent cavities and support oral health in people.

In 2015, the Department of Health and Human Services updated its recommendation of an optimal level of 0.7 parts per million, or ppm, added to drinking water based on the health benefits of tooth decay prevention. Studies have shown that fluoride added to community water systems at this level reduces dental cavities, especially in children.

And studies have conclusively shown that fluoride in toothpaste and mouthwash can also provide these benefits.

How your levels compare

This Utility

0.042 ppm

Legal Limit

4 ppm

National Average

0.485 ppm

State Average

0.475 ppm

EWG Health Guideline

Not yet determined

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2023-2025.

ppm = parts per million

Pollution Sources

Industry

Treatment Byproducts

Naturally Occurring

Filtering Options

Reverse Osmosis

Heptachlor epoxide

This Utility: 0.00315 ppb

EWG's Health Guideline: 0.006 ppb

Heptachlor epoxide

Heptachlor epoxide is a breakdown product of heptachlor, a highly toxic and carcinogenic pesticide banned in the U.S. since the 1980s.

How your levels compare

EWG Health Guideline

0.006 ppb or less

This Utility

0.00315 ppb

Legal Limit

0.2 ppb

National Average

0.000023 ppb

State Average

0.000098 ppb

Health Risks

The EWG Health Guideline of 0.006 ppb for heptachlor epoxide was defined by the California Office of Environmental Health Hazard Assessment as a public health goal, the level of a drinking water contaminant that does not pose a significant health risk. This health guideline protects against cancer.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2023-2025.

ppb = parts per billion

Pollution Sources

Agriculture

Filtering Options

Activated Carbon

Reverse Osmosis

Nitrite

This Utility: 0.0200 ppm

No EWG Health Guideline

Nitrite

Nitrite, closely related to the fertilizer chemical nitrate, comes from urban runoff and from fertilizer applied to agricultural lands to pollute drinking water. Nitrite is significantly more toxic than nitrate. Excessive nitrite in water can cause oxygen deprivation in infants and increase the risk of cancer.

How your levels compare

This Utility

0.02 ppm

Legal Limit

1 ppm

National Average

0.00392 ppm

State Average

0.0139 ppm

EWG Health Guideline

Not yet determined

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2023-2025.

ppm = parts per million

Pollution Sources

Agriculture

Runoff & Sprawl

Naturally Occurring

Filtering Options

Reverse Osmosis

Ion Exchange

Uranium

This Utility: 0.49 pCi/L

EWG's Health Guideline: 0.43 pCi/L

Uranium

Uranium is a known human carcinogen. The federal legal limit for uranium is set at 30 micrograms per liter (corresponding to parts per billion), but utilities can also report uranium in picocuries per liter (pCi/L), which is a measure of radioactivity in water. EWG translated all uranium results to pCi/L using a conversion factor developed by the EPA. With this conversion approach, the limit of 30 ppb corresponds to 20 pCi/L. Drinking water with this much uranium would cause more than 4.6 cancer cases in a population of 100,000. California set a public health goal for uranium of 0.43 pCi/L.

How your levels compare

EWG Health Guideline

0.43 pCi/L or less

This Utility

0.49 pCi/L

Legal Limit

20 pCi/L

National Average

1.09 pCi/L

State Average

0.27 pCi/L

Health Risks

The EWG Health Guideline of 0.43 pCi/L for uranium was defined by the California Office of Environmental Health Hazard Assessment as a public health goal, the level of a drinking water contaminant that does not pose a significant health risk. Three most common uranium isotopes are U-234, U-235 and U-238. All isotopes of uranium are radioactive, and the total radioactivity depends on the ratio of isotopes. This health guideline protects against cancer.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2020-2025.

pCi/L = picocuries per liter

Pollution Sources

Industry

Naturally Occurring

Filtering Options

Reverse Osmosis

Ion Exchange

Includes chemicals detected in 2021-2023 for which annual utility averages were lower than an EWG-selected health guideline established by a federal or state public health authority.

Other Contaminants Tested

✕

You're viewing EWG's latest annual update: The 2026 Data Set, which includes data through 2025.

Utilities test and report on varying schedules throughout the year, so EWG compiles the results into one annual update.

Find A Filter

Utility: 

Emil-mar Subdivision
view utility

Carbon Filters

FILTERS 2 contaminants exceeding guidelines (+1 others)

Can reduce the levels of many common contaminants.

pros

  • Lower upfront cost
  • Reduced maintenance

cons

  • Does not remove all contaminants

Reverse Osmosis

FILTERS 3 contaminants exceeding guidelines (+4 others)

Can reduce the levels of many common contaminants.

pros

  • Most effective

cons

  • Higher upfront cost
  • Requires more maintenance
  • Wastes water

Other Considerations

Ion Exchange

Pros: Softens hard water, Reduces some contaminants

Cons: Doesn’t remove all contaminants

Whole-House Filters

Pros: Useful for reducing radiologicals and TCE

Cons: Expensive to install and maintain, Risk of bacterial contamination

Explore filter options for each contaminant. See which technologies are effective at reducing specific contaminants to help you make an informed decision on the best water treatment solution for your needs.

CONTAMINANTS ABOVE HEALTH GUIDELINES activated carbon reverse osmosis ion exchange
Haloacetic acids (HAA5)
Nitrate
Total trihalomethanes (TTHMs)
OTHER CONTAMINANTS DETECTED activated carbon reverse osmosis ion exchange
Fluoride
Heptachlor epoxide
Nitrite
Uranium, combined (pCi/L)