EWG's drinking water quality report shows results of tests conducted by the water utility and provided to the Environmental Working Group by the Missouri Department of Natural Resources - Public Drinking Water Program, as well as information from the U.S. EPA Enforcement and Compliance History database (ECHO). For the latest quarter assessed by the U.S. EPA (January 2026- March 2026), tap water provided by this water utility was in compliance with federal health-based drinking water standards.

Contaminants Detected

Nitrate and nitrite

Potential Effect: cancer

This Utility: 0.900 ppm

6.4x

EWG's Health Guideline: 0.14 ppm

Nitrate and nitrite

Nitrate and nitrite enter water from fertilizer runoff, septic tanks and urban runoff. These contaminants can cause oxygen deprivation for infants and increase the risk of cancer. Nitrite is significantly more toxic than nitrate. Click here to read more about nitrate.

Nitrate and nitrite was found at 6.4 times above EWG's Health Guideline.

EWG Health Guideline

0.14 ppm or less

This Utility

0.9 ppm

Legal Limit

10 ppm

National Average

0.742 ppm

State Average

0.566 ppm

Health Risks

The EWG health guideline of 0.14 parts per million, or ppm, for nitrate and nitrite is based on the equivalent health guideline for nitrate, as defined in a peer-reviewed scientific study by EWG. This guideline represents a one-in-one-million annual cancer risk level.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2023-2025.

ppm = parts per million

Pollution Sources

Agriculture

Runoff & Sprawl

Naturally Occurring

Filtering Options

Reverse Osmosis

Ion Exchange

Radium, combined (-226 and -228)

Potential Effect: cancer

This Utility: 3.75 pCi/L

75x

EWG's Health Guideline: 0.05 pCi/L

Radium, combined (-226 and -228)

Radium is a radioactive element that causes bone cancer and other cancers. It can occur naturally in groundwater, and oil and gas extraction activities such as hydraulic fracturing can elevate concentrations.

Radium, combined (-226 and -228) was found at 75 times above EWG's Health Guideline.

EWG Health Guideline

0.05 pCi/L or less

This Utility

3.75 pCi/L

Legal Limit

5 pCi/L

National Average

0.33 pCi/L

State Average

0.45 pCi/L

Health Risks

EWG applied the health guideline of 0.05 pCi/L, defined by the California Office of Environmental Health Hazard Assessment as a public health goal for radium-226, to radium-226 and radium-228 combined. This health guideline protects against cancer.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2020-2025.

pCi/L = picocuries per liter

Pollution Sources

Industry

Naturally Occurring

Filtering Options

Reverse Osmosis

Ion Exchange

Includes chemicals detected in 2023-2025 for which annual utility averages exceeded an EWG-selected health guideline established by a federal or state public health authority; radiological contaminants detected between 2020 and 2025.

Aluminum

This Utility: 16.1 ppb

EWG's Health Guideline: 600 ppb

Aluminum

Aluminum is a metal released from metal refineries and mining operations. Too much aluminum exposure can impair children's brain development.

How your levels compare

EWG Health Guideline

600 ppb or less

This Utility

16.1 ppb

National Average

26.1 ppb

State Average

11 ppb

Health Risks

The EWG Health Guideline of 600 ppb for aluminum was defined by the California Office of Environmental Health Hazard Assessment as a public health goal, the level of a drinking water contaminant that does not pose a significant health risk. This health guideline protects against harm to the brain and nervous system.

Legal Limit

None

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2023-2025.

ppb = parts per billion

Pollution Sources

Industry

Naturally Occurring

Filtering Options

Reverse Osmosis

Barium

This Utility: 14.1 ppb

EWG's Health Guideline: 700 ppb

Barium

Barium is a mineral present in rocks, soil and water. High concentrations of barium in drinking water increase the risk of cardiovascular disease and hypertension.

How your levels compare

EWG Health Guideline

700 ppb or less

This Utility

14.1 ppb

Legal Limit

2,000 ppb

National Average

40.9 ppb

State Average

50.8 ppb

Health Risks

The EWG Health Guideline of 700 ppb for barium was defined by EWG as benchmark that protects against harm to the kidneys and the cardiovascular system.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2023-2025.

ppb = parts per billion

Pollution Sources

Industry

Naturally Occurring

Filtering Options

Reverse Osmosis

Ion Exchange

Manganese

This Utility: 0.118 ppb

EWG's Health Guideline: 100 ppb

Manganese

Manganese is a naturally occurring element that is common in food and drinking water. Excessive manganese exposures may impair children's attention, memory and intellectual capacity. Click here to read more about manganese.

How your levels compare

EWG Health Guideline

100 ppb or less

This Utility

0.118 ppb

National Average

8.37 ppb

State Average

4.67 ppb

Health Risks

The EWG Health Guideline of 100 ppb for manganese was defined by the state of Minnesota as a health risk limit, the concentration of a contaminant that can be consumed with little or no risk to health. This health guideline protects against harm to the brain and nervous system.

Legal Limit

None

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2018-2025.

ppb = parts per billion

Pollution Sources

Industry

Naturally Occurring

Filtering Options

Ion Exchange

Perfluorooctane sulfonate (PFOS)

This Utility: 0.286 ppt

EWG's Health Guideline: 0.3 ppt

Perfluorooctane sulfonate (PFOS)

Perfluorooctane sulfonate (PFOS) is a member of a group of perfluorinated chemicals used in many consumer products. PFOS and other perfluorinated chemicals can cause serious health effects, including cancer, endocrine disruption, accelerated puberty, liver and immune system damage, and thyroid changes. These chemicals are persistent in the environment and they accumulate in people. Click here to read more about perfluorinated chemicals.

How your levels compare

EWG Health Guideline

0.3 ppt or less

This Utility

0.286 ppt

Proposed Legal Limit

4 ppt

National Average

1.1 ppt

State Average

0.1 ppt

Health Risks

The EWG Health Guideline of 0.3 ppt for PFOS was defined by EPA's final toxicity value from the Office of Water’s Final Human Health Toxicity Assessment. This health guideline protects againat cardiovascular harm and harm to fetal growth.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2020-2026.

ppt = parts per trillion

Pollution Sources

Industry

Runoff & Sprawl

Filtering Options

Activated Carbon

Reverse Osmosis

Uranium

This Utility: 0.04 pCi/L

EWG's Health Guideline: 0.43 pCi/L

Uranium

Uranium is a known human carcinogen. The federal legal limit for uranium is set at 30 micrograms per liter (corresponding to parts per billion), but utilities can also report uranium in picocuries per liter (pCi/L), which is a measure of radioactivity in water. EWG translated all uranium results to pCi/L using a conversion factor developed by the EPA. With this conversion approach, the limit of 30 ppb corresponds to 20 pCi/L. Drinking water with this much uranium would cause more than 4.6 cancer cases in a population of 100,000. California set a public health goal for uranium of 0.43 pCi/L.

How your levels compare

EWG Health Guideline

0.43 pCi/L or less

This Utility

0.04 pCi/L

Legal Limit

20 pCi/L

National Average

1.09 pCi/L

State Average

0.19 pCi/L

Health Risks

The EWG Health Guideline of 0.43 pCi/L for uranium was defined by the California Office of Environmental Health Hazard Assessment as a public health goal, the level of a drinking water contaminant that does not pose a significant health risk. Three most common uranium isotopes are U-234, U-235 and U-238. All isotopes of uranium are radioactive, and the total radioactivity depends on the ratio of isotopes. This health guideline protects against cancer.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2020-2025.

pCi/L = picocuries per liter

Pollution Sources

Industry

Naturally Occurring

Filtering Options

Reverse Osmosis

Ion Exchange

Includes chemicals detected in 2021-2023 for which annual utility averages were lower than an EWG-selected health guideline established by a federal or state public health authority; chemicals detected under the EPA's Unregulated Contaminant Monitoring Rule (UCMR 3) program in 2013 to 2015 (and subsequent testing when available), for which annual utility averages were lower than an EWG-selected health guideline established by a federal or state public health authority; ; chemicals detected under the EPA's Unregulated Contaminant Monitoring Rule (UCMR 4) program in 2017 to 2020 (and subsequent testing when available), for which annual utility averages exceeded a health guideline established by a federal or state public health authority; chemicals detected under the EPA's Unregulated Contaminant Monitoring Rule (UCMR 5) program in 2023 to 2025 (and subsequent testing when available), for which annual utility averages exceeded a health guideline established by a federal or state public health authority.

Other Contaminants Tested

✕

Chemicals tested for but not detected:

1,1,1-Trichloroethane, 1,1,2-Trichloroethane, 1,1-Dichloroethylene, 1,2,4-Trichlorobenzene, 1,2-Dibromo-3-chloropropane (DBCP), 1,2-Dichloroethane, 1,2-Dichloropropane, 11-chloroeicosafluoro-3-oxaundecane-1-sulfonic aci, 2,4,5-TP (Silvex), 2,4-D, 4,8-dioxa-3H-perfluorononanoic acid (ADONA), 9-chlorohexadecafluoro-3-oxanone-1-sulfonic acid (, Alachlor (Lasso), Antimony, Atrazine, Benzene, Beryllium, Bromodichloromethane, Bromoform, Cadmium, Carbofuran, Carbon tetrachloride, Chlordane, Chloroform, Chromium (total), cis-1,2-Dichloroethylene, Cyanide, Dalapon, Dibromochloromethane, Dichloromethane (methylene chloride), Dinoseb, Endrin, Ethylbenzene, Ethylene dibromide, Fluoride, Glyphosate, Heptachlor, Heptachlor epoxide, Hexachlorobenzene (HCB), Hexachlorocyclopentadiene, Hexafluoropropylene oxide dimer acid (HFPO-DA), Lindane, Mercury (inorganic), Methoxychlor, Monochlorobenzene (chlorobenzene), MTBE, N-ethyl perfluorooctane sulfonamido acetic acid (N, N-methyl perfluorooctanesulfonamidoacetic acid, Nitrite, o-Dichlorobenzene, Oxamyl (Vydate), p-Dichlorobenzene, Pentachlorophenol, Perfluorobutane sulfonate (PFBS), Perfluorodecanoic acid (PFDA), Perfluorododecanoic acid (PFDoA), Perfluoroheptanoic acid (PFHPA), Perfluorohexane sulfonate (PFHXS), Perfluorohexanoic Acid (PFHxA), Perfluorononanoic acid (PFNA), Perfluorooctanoic acid (PFOA), Perfluorotetradecanoic acid (PFTA), Perfluorotridecanoic acid (PFTrDA), Perfluoroundecanoic acid (PFUnA), Picloram, Polychlorinated biphenyls (PCBs), Selenium, Silver, Simazine, Styrene, Tetrachloroethylene (perchloroethylene), Thallium, Toluene, Toxaphene, trans-1,2-Dichloroethylene, Trichloroethylene, Vinyl chloride, Xylenes (total)

You're viewing EWG's latest annual update: The 2026 Data Set, which includes data through 2025.

Utilities test and report on varying schedules throughout the year, so EWG compiles the results into one annual update.

Find A Filter

Utility: 

Clubb Villa Senior Living
view utility

Carbon Filters

FILTERS 0 contaminants exceeding guidelines (+1 others)

Can reduce the levels of many common contaminants.

pros

  • Lower upfront cost
  • Reduced maintenance

cons

  • Does not remove all contaminants

Reverse Osmosis

FILTERS 2 contaminants exceeding guidelines (+4 others)

Can reduce the levels of many common contaminants.

pros

  • Most effective

cons

  • Higher upfront cost
  • Requires more maintenance
  • Wastes water

Other Considerations

Ion Exchange

Pros: Softens hard water, Reduces some contaminants

Cons: Doesn’t remove all contaminants

Whole-House Filters

Pros: Useful for reducing radiologicals and TCE

Cons: Expensive to install and maintain, Risk of bacterial contamination

Explore filter options for each contaminant. See which technologies are effective at reducing specific contaminants to help you make an informed decision on the best water treatment solution for your needs.

CONTAMINANTS ABOVE HEALTH GUIDELINES activated carbon reverse osmosis ion exchange
Nitrate & nitrite
Radium, combined (-226 & -228)
OTHER CONTAMINANTS DETECTED activated carbon reverse osmosis ion exchange
Aluminum
Barium
Manganese
Perfluorooctane sulfonate (PFOS)
Uranium, combined (pCi/L)