Know Your Environment. Protect Your Health.

UTILITY

Pennwood Estates Mobile Home Park

location

Mercer County, Pennsylvania

serves

51

source

Groundwater

data through

2025

EWG 2026 Data Set

Overview

EWG's drinking water quality report shows results of tests conducted by the water utility and provided to the Environmental Working Group by the Pennsylvania Department of Environmental Protection, as well as information from the U.S. EPA Enforcement and Compliance History database (ECHO). For the latest quarter assessed by the U.S. EPA (January 2026- March 2026), tap water provided by this water utility was in compliance with federal health-based drinking water standards.

Contaminants Detected

Radium, combined (-226 and -228)

Potential Effect: cancer

This Utility: 1.61 pCi/L

32x

EWG's Health Guideline: 0.05 pCi/L

Radium, combined (-226 and -228)

Radium is a radioactive element that causes bone cancer and other cancers. It can occur naturally in groundwater, and oil and gas extraction activities such as hydraulic fracturing can elevate concentrations.

Radium, combined (-226 and -228) was found at 32 times above EWG's Health Guideline.

EWG Health Guideline

0.05 pCi/L or less

This Utility

1.61 pCi/L

Legal Limit

5 pCi/L

National Average

0.33 pCi/L

State Average

0.09 pCi/L

Health Risks

EWG applied the health guideline of 0.05 pCi/L, defined by the California Office of Environmental Health Hazard Assessment as a public health goal for radium-226, to radium-226 and radium-228 combined. This health guideline protects against cancer.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2020-2025.

pCi/L = picocuries per liter

Pollution Sources

Industry

Naturally Occurring

Filtering Options

Reverse Osmosis

Ion Exchange

Includes chemicals detected in 2023-2025 for which annual utility averages exceeded an EWG-selected health guideline established by a federal or state public health authority; radiological contaminants detected between 2020 and 2025.

Barium

This Utility: 114.0 ppb

EWG's Health Guideline: 700 ppb

Barium

Barium is a mineral present in rocks, soil and water. High concentrations of barium in drinking water increase the risk of cardiovascular disease and hypertension.

How your levels compare

EWG Health Guideline

700 ppb or less

This Utility

114 ppb

Legal Limit

2,000 ppb

National Average

40.9 ppb

State Average

49 ppb

Health Risks

The EWG Health Guideline of 700 ppb for barium was defined by EWG as benchmark that protects against harm to the kidneys and the cardiovascular system.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2023-2025.

ppb = parts per billion

Pollution Sources

Industry

Naturally Occurring

Filtering Options

Reverse Osmosis

Ion Exchange

Heptachlor

This Utility: 0.00563 ppb

EWG's Health Guideline: 0.008 ppb

Heptachlor

Heptachlor is an insecticide used for termite control until 1988. It is linked to cancer, hormone disruption and neurotoxicity.

How your levels compare

EWG Health Guideline

0.008 ppb or less

This Utility

0.00563 ppb

Legal Limit

0.4 ppb

National Average

0.000017 ppb

State Average

0.000002 ppb

Health Risks

The EWG Health Guideline of 0.008 ppb for heptachlor was defined by the California Office of Environmental Health Hazard Assessment as a public health goal, the level of a drinking water contaminant that does not pose a significant health risk. This health guideline protects against cancer.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2023-2025.

ppb = parts per billion

Pollution Sources

Agriculture

Filtering Options

Activated Carbon

Reverse Osmosis

Nitrate

This Utility: 0.0767 ppm

EWG's Health Guideline: 0.14 ppm

Nitrate

Nitrate, a fertilizer chemical, frequently contaminates drinking water due to agricultural and urban runoff, and discharges from municipal wastewater treatment plants and septic tanks. Excessive nitrate in water can cause oxygen deprivation in infants and increase the risk of cancer. Click here to read more about nitrate.

How your levels compare

EWG Health Guideline

0.14 ppm or less

This Utility

0.0767 ppm

Legal Limit

10 ppm

National Average

0.814 ppm

State Average

1.71 ppm

Health Risks

The EWG health guideline of 0.14 parts per million, or ppm, for nitrate and nitrite is based on the equivalent health guideline for nitrate, as defined in a peer-reviewed scientific study by EWG. This guideline represents a one-in-one-million annual cancer risk level.

Understanding the Data

The state and national averages were calculated using the averages of the contaminant measurements for each utility in 2023-2025.

ppm = parts per million

Pollution Sources

Agriculture

Runoff & Sprawl

Naturally Occurring

Filtering Options

Reverse Osmosis

Ion Exchange

Includes chemicals detected in 2021-2023 for which annual utility averages were lower than an EWG-selected health guideline established by a federal or state public health authority.

Other Contaminants Tested

✕

Chemicals tested for but not detected:

1,1,1-Trichloroethane, 1,1,2-Trichloroethane, 1,1-Dichloroethylene, 1,2,4-Trichlorobenzene, 1,2-Dibromo-3-chloropropane (DBCP), 1,2-Dichloroethane, 1,2-Dichloropropane, 2,3,7,8-TCDD (Dioxin), 2,4,5-TP (Silvex), 2,4-D, Alachlor (Lasso), Aldrin, Antimony, Arsenic, Asbestos, Atrazine, Benzene, Benzo[a]pyrene, Beryllium, Bromoform, Cadmium, Carbofuran, Carbon tetrachloride, Chlordane, Chloroform, Chromium (total), cis-1,2-Dichloroethylene, Combined uranium, Cyanide, Dalapon, Di(2-ethylhexyl) adipate, Di(2-ethylhexyl) phthalate, Dibromoacetic acid, Dichloroacetic acid, Dichloromethane (methylene chloride), Dieldrin, Dinoseb, Diquat, Endothall, Endrin, Ethylbenzene, Ethylene dibromide, Fluoride, Glyphosate, Haloacetic acids (HAA5), Heptachlor epoxide, Hexachlorobenzene (HCB), Hexachlorocyclopentadiene, Hexafluoropropylene oxide dimer acid (HFPO-DA), Lindane, Mercury (inorganic), Methoxychlor, Monobromoacetic acid, Monochloroacetic acid, Monochlorobenzene (chlorobenzene), Nitrite, o-Dichlorobenzene, Oxamyl (Vydate), p-Dichlorobenzene, Pentachlorophenol, Perfluorobutane sulfonate (PFBS), Perfluorohexane sulfonate (PFHXS), Perfluorononanoic acid (PFNA), Perfluorooctane sulfonate (PFOS), Perfluorooctanoic acid (PFOA), Picloram, Polychlorinated biphenyls (PCBs), Selenium, Simazine, Styrene, Tetrachloroethylene (perchloroethylene), Thallium, Toluene, Toxaphene, trans-1,2-Dichloroethylene, Trichloroacetic acid, Trichloroethylene, Vinyl chloride, Xylenes (total)

You're viewing EWG's latest annual update: The 2026 Data Set, which includes data through 2025.

Utilities test and report on varying schedules throughout the year, so EWG compiles the results into one annual update.

Find A Filter

Utility: 

Pennwood Estates Mobile Home Park
view utility

Carbon Filters

FILTERS 0 contaminants exceeding guidelines (+1 others)

Can reduce the levels of many common contaminants.

pros

  • Lower upfront cost
  • Reduced maintenance

cons

  • Does not remove all contaminants

Reverse Osmosis

FILTERS 1 contaminants exceeding guidelines (+3 others)

Can reduce the levels of many common contaminants.

pros

  • Most effective

cons

  • Higher upfront cost
  • Requires more maintenance
  • Wastes water

Other Considerations

Ion Exchange

Pros: Softens hard water, Reduces some contaminants

Cons: Doesn’t remove all contaminants

Whole-House Filters

Pros: Useful for reducing radiologicals and TCE

Cons: Expensive to install and maintain, Risk of bacterial contamination

Explore filter options for each contaminant. See which technologies are effective at reducing specific contaminants to help you make an informed decision on the best water treatment solution for your needs.

CONTAMINANTS ABOVE HEALTH GUIDELINES activated carbon reverse osmosis ion exchange
Radium, combined (-226 & -228)
OTHER CONTAMINANTS DETECTED activated carbon reverse osmosis ion exchange
Barium
Heptachlor
Nitrate