Menu

EWG's Tap Water Database — 2021 UPDATE

Donate

Carbon tetrachloride

Liberty Park Water Association

Carbon tetrachloride, a volatile carcinogenic solvent, has been used in industrial chemical production and as a dry cleaning ingredient. Read More.

Carbon tetrachloride is no longer permitted in products intended for home use in the U.S. In the past, it was widely used as a dry cleaning ingredient, fire extinguishing chemical, pesticide and chemical intermediate for manufacturing refrigerants. Carbon tetrachloride does not break down easily and can remain in groundwater for years. In addition to increasing cancer risk, carbon tetrachloride harms the liver and causes central nervous system depression, irregular heart rate, and kidney damage. Maternal exposure to carbon tetrachloride in drinking water has been associated with a risk of birth defects.

Click here to read more about carcinogenic VOCs.

 

25

Samples

0

Samples exceeding legal limit (MCL)

0

Samples exceeding
health guidelines

Testing results - average by year

 
YearAverage resultSamples takenDetectionsRange of results
2014ND40ND
2015ND40ND
2016ND40ND
2017ND50ND
2018ND40ND
2019ND40ND

ppb = parts per billion

State and national drinking water standards and health guidelines

EWG Health Guideline 0.1 ppb

The EWG Health Guideline of 0.1 ppb for carbon tetrachloride was defined by the California Office of Environmental Health Hazard Assessment as a public health goal, the level of a drinking water contaminant that does not pose a significant health risk. This health guideline protects against cancer.

EPA Maximum Contaminant
Level (MCL) 5 ppb

The legal limit for carbon tetrachloride, established in 1987, was based on analytical detection limits at the time that the standard was set. This limit does not fully protect against the risk of cancer due to carbon tetrachloride exposure.

ppb = parts per billion

All test results

Date Lab ID Result
2014-01-284417-001-1350ND
2014-04-024417-001-1240ND
2014-08-064417-001-1220ND
2014-10-224417-001-1115ND
2015-01-054417-001-1150ND
2015-04-024417-001-1150ND
2015-07-014417-001-0840ND
2015-10-074417-001-1120ND
2016-01-134417-001-1215ND
2016-04-044417-001-1435ND
2016-07-054417-001-1400ND
2016-11-144417-001-1115ND
2017-01-044417-001-1300ND
2017-02-024417-001-1100ND
2017-04-244417-001-1120ND
2017-07-064417-001-1300ND
2017-10-034417-001-1140ND
2018-01-024417-001-1250ND
2018-04-044417-001-1300ND
2018-07-164417-001-1130ND
2018-10-014417-001-1340ND
2019-01-024417-001-1100ND
2019-04-014417-001-1300ND
2019-07-024417-001-0945ND
2019-10-014417-001-1230ND